Metro tempo sync

Magerit Forum

Tagged: , ,

Viewing 2 reply threads
  • Author
    Posts
    • #4563
      aaron
      Participant

      Hello, I purchased Metro a few weeks ago and I really love your module. It is quite powerful and fun to play. But I have a doubt with the external clock sync and I would like to know how to use it properly. If I pause and play the sequencer from my clock source, It sometimes starts out of sync. Do you have any idea why this happens? Thanks

    • #4565
      Magerit
      Keymaster

      Hello, Aaron! If you use an external clock signal, METRO will auto sync itself 1.5 seconds after you paused the clock signal. Why do we need to wait 1.5 seconds? METRO use a ratio-counter system in order to sync all different ratios of each channel. Each ratio has a multiplier synced to that counter. If we reset always that counter on each beat, Triplets, Half and other ratios won’t work properly. So we decided to add a reset only when you restart the sequencer: all sequencers will start in the step ONE and the ratio counter will be set to 0. In order to add an auto reset, we stablished a limit of 1.5 seconds which is 40 BPM, the limit METRO can read. This may be difficult to understand… haha.

      If you don’t use the external clock (and use METRO’s internal clock), you do not need to wait 1.5 seconds, you can play and pause at the speed you want.

      Regards!

    • #4568
      aaron
      Participant

      Thanks! Now I understand it and it works perfectly 🙂

Viewing 2 reply threads
  • You must be logged in to reply to this topic.